HLR3800-4G3D Potential type Motor starting relay single-phase motor (compressor) the starting relay mainly uses in exchanging 50/60HZ, the voltage to the 277V control circuit and the nominal current to the 16A power circuit, through starts the electric capacity, the starting single-phase motor (compressor). Is suitable in the air conditioning, the refrigerator and so on industry machine electric appliance equipment and so on domestic electric appliances and water pump.
2 、Type and meaning
HL
R
3800
–
4
G
3
D
Hongli Electric
Relay
Type
“Y” :Individual Box Pack “–” :Factory Bulk Pack
Coil Number
A: Expressedt 60HZ
not have symbolized: Expresses 50HZ
Operating characteristics
Operating Position
Terminal configuration
2.Product explanation and major technique parameter
★ Fixed isolation voltage Ui : 600V
★ Fixed working voltage Ue : AC 277V
★ Fixed operating current: Ie=16A , Ith=35A
★ Normal connection and breaking current: 35A 、Breaking current ability: 96A
★ Mechanical life> 1,000,000 times
★ Electricity life> 100,000 times
★ Coil working voltage scope: 70% ~110%Us
★ Product coil working voltage Us=AC 170 ~ 502V
★ The relay winding (cold clean criticality) can attract reliably in AC 170 ~ 502V gathers, the released voltage is not lower than AC 40V.
3.Conforms To The Standard
Conforms To National Standard And International Standard
1 、Conforms To IEC 60730;GB14048.5,UL508 Standard 。
2 、Approved By ISO9001 System Certification(SGS)、 CCC,TUV,CE,UL and Safe Certification
CCC Certification Number:
2005010303156716
TUV Certification Number :
B 05 06 56608 001
UL Files Number:
E251539
CE Certification Number :
N8N 05 06 56608 002
4.Technology Data
Part No.
Continuous Coil
Voltage (V)
Pick-up (V)
Drop-out (V)
Max.
Min.
Max.
HLR3800-7AD3D
168
140
153
45
HLR3800-5AN3D
395
262
290
140
HLR3800-2AF3D
332
171
184
90
HLR3800-5AI3D
395
204
233
130
HLR3800-4AP3D
420
300
328
121
HLR3800-6AQ3D
502
314
342
135
HLR3800-3AG3D
375
180
195
105
5.Specification
HLR3800 Series Potential Relay DownLoad PDF DataSheet